Tool to support the calculation of electrical installations that will allow the user (designer/electrician/technician) to perform electrical calculations easily and quickly.
· Dimensioning complete of low voltage circuits with the most frequent installation methods
· Phase cable size, neutral, protective conductor
· Criteria based on the admissible current of the cable, voltage drop and overcurrent protection
· Designation of the most used cables.
· Circuits with automatic circuit breaker until In=4000 A (Ir rating setting), maximum fuse In=1600 A (gG type), maximum 12 conductors parallel per phase, maximum size 630 mm²
· Short-circuits, including MV network, LV lines and final circuit
· Estimate of the maximum short-circuit current (simplified method)
· Maximum protected length for minimum short circuit (approximate method)
· Earthing system with diferentes types of electrodes (rods, buried conductor, rings and grid)
· Distance between the earthing systems
· Forecast of loads of a building destined to houses with several sections: dwellings, common services, commercial premises/offices and garage with/without infrastructure for recharging electric vehicles
· Reactive power of the capacitor bank for the compensation of the power factor (cos φ) and capacity (µF) of the capacitors
· C/K Factor for automatic capacitor bank
· Frequency resonance capacitors
· Compensation of the power factor for a three-phase transformer
· Choice of installation system in the function of the circuit, cable and its situation
· Overvoltage due to defects to earth in medium voltage MV depending on the earthing systems
· Power in an unbalanced three-phase system
· Overvoltages due to loss of neutral conductor, earth fault and short circuit
· Electricity parameters of a single-phase or three-phase (balanced)
· Transformer performance
· Secondary voltage of a transformer acoording to switch position
· Distribution of load of transformers in parallel
· K-Factor transformer
· Current transformer
· Verification resistance of the assembly to short-circuits
· Dissipated power of a assembly
· Size of trays and conduits
· Conduits characteristics according to the installation method
· Conversions of wire sizes (mm²-awg) and conduits threads
· Impedance, resistance and reactance of a cable
· Representation of the curves of the protections
· International protection IP - IK
Parameter settings for calculations:
· Constants (voltages, conductivity, temperatures, etc.) that affect electrical calculations
· Protections (circuit breakers and fuses)
· Selection of minimum rate for circuit-breakers with regulation and maximum cable size for multi-conductor grouping per phase
· Method estimation of the reactance
· Conductivity of the conductor depending on the current of the circuit (constant, according to the expected current, maximum cable temperature)
· Use reduction factors by grouping cables/circuits
· Use of factors of diversity/utilization
· Reference documents: IEC Standards, REBT (sp), Technical Application Guide, (UE) 2016/364
IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION
- Apple App Store
- 付費
- 生產力
商店排名
- -
ElectroMaster Pro - Electro-technical and Electrical Tool
ElectroMaster Pro, a simple Electro-technical and Electric tool, made for students and professionals of the job.
** NO ADS**
ElectroMaster is divided into three sections: Electrical, Basic Knowledge and Advanced Electrical.
In the sections of Electrical and Advanced Electrical there is a practical and a theoretical part, in the Basic Knowledge section there are the main theoretical concepts of electricity.
Electrical contents:
Ohm's Law
Resistors in series
Resistors in parallel
Capacitors in series
Capacitors in parallel
Power calculation
Three-phases power calculation
Star-delta transformation
Delta-star transformation
Resistors color codes
Voltage divider
Current divider
Motor from three phases to single phase
Thevenin's Theorem
Norton's Theorem
Kirchhoff's Voltage Law
Basic knowledge:
Current
AC
Voltage
Resistance
Capacitor
Relay
Transformer
Self-restraint
Circuit breaker
ELCB
Synchronous motor
Asynchronous motor
Dc Motors
Contactors
IP Protections
Semiconductors
Logic Gates
Advanced Electrical:
Wire Size - Voltage drop criteria
Wire Size - Power loss criteria
Power Factor Correction
Power loss
Maximum line length
Voltage drop
Fuses size
Wire resistance
Developer: Carlo Terracciano
Content manager: Pietro Beccaria
- Apple App Store
- 付費
- 生產力
商店排名
- -
InstElectric Pro - Electricity與 ElectroMaster Pro 比較排名
比較過去 28 天的 InstElectric Pro - Electricity 排名趨勢與 ElectroMaster Pro
排名
無可用數據
InstElectric Pro - Electricity vs. ElectroMaster Pro ranking by country comparison
比較過去 28 天的 InstElectric Pro - Electricity 排名趨勢與 ElectroMaster Pro
所有類別
無可用數據
生產力
使用我們的免費試用版,與所有網站進行比較
InstElectric Pro - Electricity VS.
ElectroMaster Pro
11月 26, 2024