Prysmian Group Conductor Amps vs Medium Voltage Calculations Usage & Stats

Prysmian Group's Ampacity Calculator is a quick and easy tool to get conductor ampacities for different temperature ratings. It is designed for contractors, electricians, and other electrical professionals. The ampacity values are taken from table T310.15 (B) (16). The Ampacity Calculator provides the following options: Code Selection for NEC® 2011, 2014, and 2017. Metric or standard conductors Choice of copper and aluminum conductor material Ampacity numbers according to 60°C, 75°C, and 90°C temperature ratings Ambient Temperature Correction Factors for temperatures other than 30°C ambient temperature
  • Apple App Store
  • Free
  • Productivity

Store Rank

- -

The most complete tool to support the calculation of high voltage electrical installations. Free sections: - Determination of the characteristics of the equipment: rated voltage (Ur), withstand at industrial frequency (Ud), withstand type of lightning (Up), short-term current (Ik) - Sizing of low and medium voltage insulated cables (≤ 30 kV) - Calculation criteria for admissible current, voltage drop, short circuit and protection, consideration of different factors for reducing the admissible current: temperature, thermal resistivity of the ground, grouping, sun exposure, etc. - Multiple installation methods: tray, buried, under pipe, in the air ... - Visualization of protection relay trip curve and MV cable admissible current - Protection with transformer limiting fuses - Earth fault current calculation (isolated neutral and earth) - PE conductor - Transformer performance and voltage drop - Primary/secondary conversions in voltage and current transformers - Secondary voltage of a transformer acoording to switch position - Calculation of the transformation center ventilation needs - Five safety rules - Consult ANSI codes electrical protections - Tray sizing - Representation of 1 IEC curve - Parameter configuration Voltages, frequency, conductivity of the conductor material, temperature MV specific: list type, cable bundle (flat / staggered) Regulation of LV protections - Possibility of sharing results Purchases In-App: - Calculation of short circuits and impedances with the maximum and minimum values, type diagram with the following configuration: Network, Transformer, MV line, LV line - Selection of voltage and current transformers (protection and measurement), capacitor bank of the transformer, calculation of the number of insulators - Protection and adjustment of the transformer overcurrent relay, selectivity with low voltage switch (Ir, Isd, Ii), graph of the actuation curves and identification of characteristic points - Calculation of medium voltage line (short line model, single circuit) with conductors: AL1 / ST1A (LA), AL1 / S20SA (LARL), AL3 / ST1A (DA), AL3 (D) - Dimensioning and checking of protective and service grounding installation, system configuration, calculation of Howe parameters, step and contact voltages, distance between grounding, single grounding, additional safety measures and results checking - Representation of up to 3 IEC curves with different voltage levels - Removal of ads with any purchase made IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION Attribution icon: Icons made by smalllikeart from www.flaticon.com
  • Apple App Store
  • Free
  • Productivity

Store Rank

- -

Prysmian Group Conductor Amps vs. Medium Voltage Calculations ranking comparison

Compare Prysmian Group Conductor Amps ranking trend in the past 28 days vs. Medium Voltage Calculations

Rank

No Data Available

Prysmian Group Conductor Amps vs. Medium Voltage Calculations ranking by country comparison

Compare Prysmian Group Conductor Amps ranking trend in the past 28 days vs. Medium Voltage Calculations

No Data to Display

Compare to any site with our free trial

Get started
Prysmian Group Conductor Amps VS.
Medium Voltage Calculations

December 13, 2024