WEG Data Viewer vs Medium Voltage Calculations Usage & Stats

Access technical documents for WEG products. WEG Data Viewer is a tool to easily search data sheets, drawings, test reports, manuals, bulletins and other technical documents related to electric motors, alternators, automation equipment and ink manufactured by WEG.
  • Apple App Store
  • Free
  • Productivity

Store Rank

- -

The most complete tool to support the calculation of high voltage electrical installations. Free sections: - Determination of the characteristics of the equipment: rated voltage (Ur), withstand at industrial frequency (Ud), withstand type of lightning (Up), short-term current (Ik) - Sizing of low and medium voltage insulated cables (≤ 30 kV) - Calculation criteria for admissible current, voltage drop, short circuit and protection, consideration of different factors for reducing the admissible current: temperature, thermal resistivity of the ground, grouping, sun exposure, etc. - Multiple installation methods: tray, buried, under pipe, in the air ... - Visualization of protection relay trip curve and MV cable admissible current - Protection with transformer limiting fuses - Earth fault current calculation (isolated neutral and earth) - PE conductor - Transformer performance and voltage drop - Primary/secondary conversions in voltage and current transformers - Secondary voltage of a transformer acoording to switch position - Calculation of the transformation center ventilation needs - Five safety rules - Consult ANSI codes electrical protections - Tray sizing - Representation of 1 IEC curve - Parameter configuration Voltages, frequency, conductivity of the conductor material, temperature MV specific: list type, cable bundle (flat / staggered) Regulation of LV protections - Possibility of sharing results Purchases In-App: - Calculation of short circuits and impedances with the maximum and minimum values, type diagram with the following configuration: Network, Transformer, MV line, LV line - Selection of voltage and current transformers (protection and measurement), capacitor bank of the transformer, calculation of the number of insulators - Protection and adjustment of the transformer overcurrent relay, selectivity with low voltage switch (Ir, Isd, Ii), graph of the actuation curves and identification of characteristic points - Calculation of medium voltage line (short line model, single circuit) with conductors: AL1 / ST1A (LA), AL1 / S20SA (LARL), AL3 / ST1A (DA), AL3 (D) - Dimensioning and checking of protective and service grounding installation, system configuration, calculation of Howe parameters, step and contact voltages, distance between grounding, single grounding, additional safety measures and results checking - Representation of up to 3 IEC curves with different voltage levels - Removal of ads with any purchase made IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION Attribution icon: Icons made by smalllikeart from www.flaticon.com
  • Apple App Store
  • Free
  • Productivity

Store Rank

- -

WEG Data Viewer vs. Medium Voltage Calculations ranking comparison

Compare WEG Data Viewer ranking trend in the past 28 days vs. Medium Voltage Calculations

Rank

No Data Available

WEG Data Viewer vs. Medium Voltage Calculations ranking by country comparison

Compare WEG Data Viewer ranking trend in the past 28 days vs. Medium Voltage Calculations

No Data to Display

Compare to any site with our free trial

Get started
WEG Data Viewer VS.
Medium Voltage Calculations

December 25, 2024