NOTE: Read the description CAREFULLY before downloading!
Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).
Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages using swipe gestures or buttons.
Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.
Advantages:
Excellent technical support.
Free updates.
Graphic HMIs with multi touch function can be created in minutes.
Free-of-charge development tool with test run feature.
Virtually unlimited number of pages, objects and variables.
Does not require any third-party services.
Genuine native app.
Features:
Parameters for communication such as IP address, port number, protocol, etc. can be specified per page.
Automatic polling of all variables displayed in the current page, no need for separate tag list.
Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
Prioritized event-driven transfer to the controller.
Pages are edited in the measurement unit dp (Density Independent Pixels).
Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
Detailed diagnostics of connection and communication.
Variable areas for system variables, local variables and constants.
Possibility of automatic return to the start page after some time of inactivity.
Selectable order for high and low words of 32-bit variables in the Modbus protocol.
Poll interval can be set do save data traffic or battery.
Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
Ability to test run pages in the development tool.
LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
Background color for pages can be selected.
Modbus Device ID can be changed with GUI objects during operation.
Image buttons.
Password fields.
Floating point and hexadecimal number formatting.
Timestamp for page files.
Hyperlinks.
Document information in page files.
Implemented protocols in the current version:
Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.
Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).
Modbus RTU: Class 0 and 1.
Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.
(Default value for highest Siemens S7 databock is 255.)
Free-of-charge development tool for creating the pages to be used by Odrid HMI:
https://www.idea-teknik.com/odrid_hmi_download.html
Manual:
https://www.idea-teknik.com/odrid_hmi_manual.html
Version history:
https://www.idea-teknik.com/odrid_hmi_version_history.html
Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.
S7 and STEP 7 are trademarks of Siemens AG.
- Apple App Store
- Paid
- Productivity
Store Rank
- -
SIMATIC Notifier
The intelligent solution for direct notifications from your machine or plant.
With SIMATIC Notifier you transform your smartphone into a message service for production: Depending on the configuration, the Notifier automatically informs you about important events from your automation systems. This enables you to react quickly and specifically to problems and malfunctions, thus increasing the availability and productivity of your plant. The reduced downtimes lead to significant time and cost savings.
SIMATIC Notifier App is easy to integrate into plants, production lines and machines and offers fast and user-friendly web-based configuration within the Notifier Server.
Note: A licensed SIMATIC Notifier Server (software download) is required for operation. Further information on the product, product videos and download links can be found at www.siemens.com/simatic-notifier.
The most important functions at a glance
• Create notifications on your mobile devices based on tags and variables (OPC UA DA, S7-300/400 and S7-1200/1500)
• User and role management for individual alarming
• Various notification categories: Alert, Warning & Information
• Encrypted communication via WiFi
• Low hardware requirements for Notifier Server (Windows PC)
• Use your own smartphone
Interested? Further information can be found in the following videos:
https://www.youtube.com/watch?v=ydb-_0JU0DE
https://www.youtube.com/watch?v=FSNbLZgs_ps
Answers to questions about setup and use of the app can be found in the manual under the following link: http://www.siemens.com/simatic-notifier
Terms of Use and Privacy Policy:
By downloading this application, you agree to the SIEMENS End User License Agreement for Mobile Applications at https://support.industry.siemens.com/cs/ww/en/view/109480850
You may not use or otherwise export or re-export the Application except as permitted by the laws of the United States and the laws of the country in which the application was acquired. In particular, the application may not be exported or re-exported (a) to embargoed U.S. countries or (b) to persons on the U.S. Treasury Department's "Specially Designated Nationals" list or the U.S. Department of Commerce's "Denied Persons" or "Denied Entity" list. By using the application, you warrant that you are not located in any of these countries and that you are not on any of these lists. You will not use the application for any purpose prohibited by U.S. law, including but not limited to developing, designing, manufacturing or producing nuclear weapons, missiles, chemical or biological weapons.
- Apple App Store
- Free
- Productivity
Store Rank
- -
Odrid HMI vs. SIMATIC Notifier ranking comparison
Compare Odrid HMI ranking trend in the past 28 days vs. SIMATIC Notifier
Rank
No Data Available
Odrid HMI vs. SIMATIC Notifier ranking by country comparison
Compare Odrid HMI ranking trend in the past 28 days vs. SIMATIC Notifier
All categories
No Data Available
Productivity
Compare to any site with our free trial
Odrid HMI VS.
SIMATIC Notifier
December 13, 2024