Vishwa Agnihotra 对比 DCON 的使用情况和统计数据

Agnihotra. Agni means FIRE and hotra means to offer unto the fire to create a healing effect. Agnihotra, also known as Homa Therapy or Fire Therapy is an Vedic technique that enhances and nourishes human lives creating an equilibrium between the nature within us and around us by tuning our mind and body with rhythm of nature. It’s a process of purification whose positive results have been established by scientists, doctors, ecologists both modern and ancient. Agnihotra is a fabulous and elementary healing therapy practiced by people worldwide as it doesn’t have any religious or national nuances attached to it. Agnihotra can be performed by anyone, anywhere, at home, in the garden, office etc in a clean and tidy environment. The process is tuned to the biorhythm corresponding with sunrise & sunset, hence Agnihotra is performed precisely at given local sunrise & sunset timings. Agnihotra app is built to provide Agnihotra timings based on given locations. This app can also throws notifications to remind an individual to perform Agnihotra. Also multiple locations can be added so travelers can easily switch between location to get Agnihotra time for that location without the need of internet. Apart from this monthly Agnihotra timing calendar can be viewed and yearly Agnihotra timing chart can be downloaded as a PDF file which can be further shared or printed.
  • Apple 应用商店
  • 免费
  • 公共事业

商店排名

- -

About this app: DCON application works with Mobitech’s hardware only. It’s an IOT(Internet of things) controller to monitor and control the irrigation and fertigation system of agricultural farm. Features of DCON. 1. We can add 10 numbers of users in a device, and operate seamlessly anywhere in the world. 2. There are different types of timers given to run the motor and valves. They are classified as below: Manual mode. Time based manual mode: This mode is used to run the motor immediately based on time. Flow based manual mode: Flow based mode is used to run the motor immediately based on flow. Manual fertigation mode: Manual fertigation mode is used to run the motor immediately based on inject fertilizer. Backwash mode Manual backwash mode: Turning ON the Manual backwash mode helps to clean the filters. Automatic Backwash mode: Automatic Backwash mode is totally differ from manual backwash mode, It is based on the difference in the input and output pressure. Cyclic mode Cyclic timer: This cyclic timer is automatic and presets cyclically. We can add a maximum of 200 timers in a queue based on the timer. Cyclic Flow:This cyclic flow is automatic and presets cyclically. We can add a maximum of 200 timers in a queue based on flow. Cyclic fertigation mode: In cyclic fertigation mode we can add up to 200 timers in cyclically to inject the fertilizer Sensor based cyclic mode: sensor based cyclic mode is used to operate the motor automatically based on the soil moisture level Real timer mode Real timer : This mode is based on the real time,We need to set Start time and End time. Fertigation mode Fertigation mode with calendar: Turning ON this mode, which helps to inject the relevant fertilizer on the selected date and time. Fertigation mode without calendar: Turning ON this mode, which helps to inject the fertilizer on a daily basis. Fertigation mode with EC&PH : EC&PH mode is depending on the EC and PH valve this timer will automatically inject the fertilizers. Autonomous irrigation mode Autonomous irrigation time based: This mode is used to help the motor Turn ON and OFF automatically,which is based on soil moisture and time Autonomous irrigation flow based: This mode is used to help the motor Turning ON and OFF automatically, which is based on soil moisture and flow based. 3. There are different types of functions are provided to protect the motor. Dryrun: If the running ampere value decreases below the set level, DCON will turn off the motor automatically. Overload: If the running ampere value increases above the set level, DCON will turn off the motor automatically. Power Factor: If the power factor value increases above the set level, DCON will turn off the motor automatically. High pressure: If the high pressure value increases above the set level, DCON will turn off the motor automatically. Low pressure: If the pressure value decreases below the set level, DCON will turn off the motor automatically. Phase Preventer: If any one of the phases fails, DCON will turn off the motor automatically. Current imbalance: If the ampere difference was greater than the set level, the DCON will turn OFF the motor automatically. Low and high voltage alert: If the voltage value decreases below or increases above the set level, DCON will send an alert message to the registered mobile number. If enabling low and high voltage motor off option, the motor will OFF automatically. 4. It can run the motor automatically based on Water Level using Level Sensor. 5. Logs- You can view and download the last 3 months logs 6. Weather station: The measurements taken include temperature, atmospheric pressure, humidity, wind speed, wind direction, and precipitation amounts.
  • Apple 应用商店
  • 免费
  • 公共事业

商店排名

- -

Vishwa Agnihotra与DCON排名比较

对比 Vishwa Agnihotra 与 DCON 在过去 28 天内的排名趋势

排名

没有可用的数据

Vishwa Agnihotra 对比 DCON 的排名,按国家/地区比较

对比 Vishwa Agnihotra 与 DCON 在过去 28 天内的排名趋势

无数据可显示

通过免费试用版比较任何网站

开始使用
Vishwa Agnihotra VS.
DCON

十二月 24, 2024