- BACnet HMI | HMI5
- BACnet HMI | HMI5 Vs. W-BACnet
BACnet HMI | HMI5 與 W-BACnet 使用情況與統計
Note: refer to the documentation to create the configuration file and to transfer it with iTunes File Sharing.
Transform your iPhone or iPad into a BACnet HMI (Human-machine interface).
Create a mobile BACnet application using the web technologies: HTML5, CSS, and JavaScript
Create mobile applications with native BACnet access using standardized web APIs.
A JavaScript API is provided to natively access devices on a BACnet network.
+ Access BACnet devices on the local network (Wi-Fi) or Register as a Foreign Device to a remote network through the cellular network or Wi-Fi.
+ Allows to perform read and write operations on the property Present_Value for objects of the following type:
Binary Input, Binary Output, Binary Value, Analog Input, Analog Output, Analog Value, Multi-state Input, Multi-state Output and Multi-state Value.
+ Allows to read most available properties of the BACnet objects.
+ Support for write command Priority (selectable priority and NULL value / Relinquish Default).
+ Create dynamic user interface for tablets, phones and other devices.
* Documentation:
https://bacmove.com/bacnet-hmi-hmi5
https://bacmove.com/bacnet-hmi-hmi5-guide
BIBB:
DS-RP-A
DS-RP-B
DM-DDB-A
DM-DDB-B
DS-WP-A
BACnet® is a registered trademark of ASHRAE.
- Apple App Store
- 付費
- 公共設施
商店排名
- -
The W-BACnet app has arrived! Upgrade firmware for LumenRadio W-BACnet devices by connecting to and upgrading the LumenRadio Gateway in the network through the app. In the Network map you will find a system overview where you can see signal strength, edit names of wireless nodes as well as seeing the health of the RS485 bus including which BACnet MS/TP address that is connected to that wireless node.
You can also connect to any node in the network and change their name (up to 20 characters).
The W-BACnet app requires W-BACnet firmware 3.1.1 and above, which can be downloaded from the LumenRadio support webpage. Note that you need to install FW 3.1.1 or above on the gateway from the nRF connect app to enable the functionality. It is also required to have at least 3.0.0 or above on all nodes in the network. You will need to update all nodes individually if they are on version 2.2.3. This will be the last time this is required. All future updates can be done by either this app or from the nRF connect app.
- Apple App Store
- 免費版
- 公共設施
商店排名
- -
BACnet HMI | HMI5與 W-BACnet 比較排名
比較過去 28 天的 BACnet HMI | HMI5 排名趨勢與 W-BACnet
排名
無可用數據
各國 BACnet HMI | HMI5 vs. W-BACnet 排名比較
比較過去 28 天的 BACnet HMI | HMI5 排名趨勢與 W-BACnet
無可顯示數據
使用我們的免費試用版,與所有網站進行比較
BACnet HMI | HMI5 VS.
W-BACnet