Ampère Mobile против Medium Voltage Calculations Использование & Stats

App required for installers, designers and electricians, who wish to have at hand all the tools necessary for a correct dimensioning and verification of the electrical plant. Now you have all the design data available in the places where you need an immediate evaluation and control. There are two tools: 1) Project calculation Allows a fast calculation of the current absorbed by a load in low and medium voltage, the dimensioning of the electric cable, the verification of the voltage drop and of the working temperature of the cable. The App provides the freedom to set any voltage and frequency (50-60 Hz, DC) power supply, the load type (three-phase, single phase), the power factor and the ambient temperature. There are multiple International low voltage installation tables (CEI 64-8, IEC 60364, NF C 15-100, BS 7671, UNE 20460, NBR 5410) and as many for medium voltage. 2) Projects The design file of an electrical plant created by the program Ampere of Electro Graphics can be sent directly to your mobile device via email attachment or by copying the files on the device. Projects can be opened, viewed and edited on the device and then transferred to the computer with the same tools, and then proceed to upgrade the project using the "Update from Ampere Mobile". You can then work directly on the 'field' with your project Ampere, run verifications on sight, shooting and storing pictures for each unit, edit useful comments to be reviewed calmly in the office or to send to your colleagues in real time. The installer can use the app to share with you the project itself, promptly reporting any problems that may arise during the implementation phase of the electrical plant, and thus receive immediately any reviews. The application does not need internet connection.
  • Apple App Store
  • Бесплатный
  • Продуктивность

Рейтинг магазина

- -

The most complete tool to support the calculation of high voltage electrical installations. Free sections: - Determination of the characteristics of the equipment: rated voltage (Ur), withstand at industrial frequency (Ud), withstand type of lightning (Up), short-term current (Ik) - Sizing of low and medium voltage insulated cables (≤ 30 kV) - Calculation criteria for admissible current, voltage drop, short circuit and protection, consideration of different factors for reducing the admissible current: temperature, thermal resistivity of the ground, grouping, sun exposure, etc. - Multiple installation methods: tray, buried, under pipe, in the air ... - Visualization of protection relay trip curve and MV cable admissible current - Protection with transformer limiting fuses - Earth fault current calculation (isolated neutral and earth) - PE conductor - Transformer performance and voltage drop - Primary/secondary conversions in voltage and current transformers - Secondary voltage of a transformer acoording to switch position - Calculation of the transformation center ventilation needs - Five safety rules - Consult ANSI codes electrical protections - Tray sizing - Representation of 1 IEC curve - Parameter configuration Voltages, frequency, conductivity of the conductor material, temperature MV specific: list type, cable bundle (flat / staggered) Regulation of LV protections - Possibility of sharing results Purchases In-App: - Calculation of short circuits and impedances with the maximum and minimum values, type diagram with the following configuration: Network, Transformer, MV line, LV line - Selection of voltage and current transformers (protection and measurement), capacitor bank of the transformer, calculation of the number of insulators - Protection and adjustment of the transformer overcurrent relay, selectivity with low voltage switch (Ir, Isd, Ii), graph of the actuation curves and identification of characteristic points - Calculation of medium voltage line (short line model, single circuit) with conductors: AL1 / ST1A (LA), AL1 / S20SA (LARL), AL3 / ST1A (DA), AL3 (D) - Dimensioning and checking of protective and service grounding installation, system configuration, calculation of Howe parameters, step and contact voltages, distance between grounding, single grounding, additional safety measures and results checking - Representation of up to 3 IEC curves with different voltage levels - Removal of ads with any purchase made IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION Attribution icon: Icons made by smalllikeart from www.flaticon.com
  • Apple App Store
  • Бесплатный
  • Продуктивность

Рейтинг магазина

- -

Ampère Mobile vs. Medium Voltage Calculations ranking comparison

Compare Ampère Mobile ranking trend in the past 28 days vs. Medium Voltage Calculations

Rank

Нет данных

Рейтинг Ampère Mobile против Medium Voltage Calculations в сравнении по странам

Сравните динамику рейтинга Ampère Mobile за последние 28 дней с динамикой рейтинга Medium Voltage Calculations.

Нет данных для отображения

Сравните данные с любым сайтом, воспользовавшись бесплатной пробной версией

Начать
Ampère Mobile VS.
Medium Voltage Calculations

декабрь 15, 2024