This app is used to Calculate Required Surface area of tubular Heat Exchangers and No. of Tubes Required for Desired Heat Exchange is calculated in this app.
This app is useful for those who are working in process industry, heat exchanger manufacturing industry and fabrication of process equipment field.
In this app Surface area of heat exchanger is calculated by taking input from user as Tube Diameter in mm, tube length in mm and No of Tubes of heat exchanger.
In this app No of Tubes required for desired heat exchange is calculated by taking input from user as Tube Diameter in mm, tube length in mm and Surface area of heat exchanger.
it is very handy tool for Tubular heat exchanger maufacturing processional., mechanical engineers and proces engineers.
- App Store di Apple
- A pagamento
- Servizi
Classifica degli store
- -
PID Tuner uses the IMC (Internal Model Control) method to calculate PID tuning parameters. I’ve tried a lot of tuning methods over the years and have found this one to be the best. The app is written for the iPad to show all the information on one page.
The program calculates:
PID Parameters:
Controller Gain (Kc)
Integral Time (Ti)
Derivative Time (Td)
For process types
First Order with Dead Time (FO)
Second Order with Dead Time (SO)
Integrating or Long Time Constant with Dead Time (I)
For controller types
Parallel (non-interacting)
c(s) = Kc (1 + 1/(Ti s) + Td s)
Series (interacting)
c(s) = Kc (Ti s + 1)/(Ti s)(Td s + 1)
For controller modes
PID
PI
You can either enter the process gain (Kp) directly or enter the changes in the controlled virable (CV) and manipulated variable (MV).
Tuning aggression is adjusted using the slider to set the closed loop time constant to the process time constant ratio (λ/Ƭ).
The closed loop time constant (λ) is the time the controller is expected to reach set point (plus the dead time (ϴ)). Setting the closed loop time constant to process time constant ratio (λ/Ƭ) to 1.0 will make the MV change to its final value and allow the process to settle out to the setpoint. Setting (λ/Ƭ) greater than 1.0 will give a slower responce. Setting (λ/Ƭ) less than 1.0 will cause the MV to make a larger change and then reduce to its final value. Tight tuning would be to set the close loop time constant to the dead time.
Use the Integrating Process type (Ƭ = ∞) for both integrating processes or processes with long time constants. These processes use the maximum slope as the process gain. Tuning aggression for these processes is determined by setting the closed loop time constant to the dead time ratio (λ/ϴ). Once again, setting the closed loop time constat to the dead time gives tight control.
References:
“Probably the test simple PID tuning rules in the World,” Sigurd Skogestad, Jounal of Process Control, July 3, 2001
“Consider the generalized IMC-PID method for PID controller tuning of time-delay processes,” Y. Lee, S. Park, M. Lee, Hydrocarbon Processing, January 2006
- App Store di Apple
- A pagamento
- Servizi
Classifica degli store
- -
Heat Exchanger Area ProRanking a confronto con PIDTune
Confronta la tendenza di classifica Heat Exchanger Area Pro nei ultimi 28 giorni rispetto a PIDTune
Rank
Nessun dato disponibile
Classifica Heat Exchanger Area Pro vs. PIDTune per paese a confronto
Confronta la tendenza di classifica Heat Exchanger Area Pro nei ultimi 28 giorni rispetto a PIDTune
Tutte le categorie
Nessun dato disponibile
Servizi
Fai confronti con qualsiasi sito con la nostra prova gratuita
Heat Exchanger Area Pro VS.
PIDTune
16icembre d, 2024