MODTest Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via many BLE modules equipped with Bluetooth 4 or higher that provide UART bridging capability.
Tap the Setup button to enter the appropriate parameters for your device. Return to the main display to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).
The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.
The app supports MODBUS-TCP, -RTU, and -ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232/RS485 serial data communication. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.
The following MODBUS function codes are supported:
1 – Read Coils
2 – Read Discrete Inputs
3 – Read Holding Registers
4 – Read Input Registers
5 – Write Single Coil
6 – Write Single Register
7 – Read Exception Status
15 – Write Multiple Coils
16 – Write Multiple Registers
17 – Report Server ID
Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.
The app supports a wide range of data representations including:
Unsigned Integer: 16 bit, 32 bit, and 64 bit
Signed Integer: 16 bit, 32 bit, and 64 bit
Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
Hex Data Strings: 16-bit, 32 bit, and 64-bit
Bit and Byte Representations for Coils & Discrete Inputs
The app also supports the following "reverse modes" of floating point data storage:
Atomic 8-bit Little Endian
Atomic 16-bit Little Endian
PDP Endian
Bit Reversal
When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). Continuous polling is also supported. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made. The app scans for UART Service & TX/RX Characteristic UUIDs from BLE devices by a number of manufacturers. The UUIDs that are supported are detailed in the app User Guide.
A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.
When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.
The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.
- Apple App Store
- Payant
- Productivité
Classement dans le store
- -
NOTE: Read the description CAREFULLY before downloading!
Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).
Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages using swipe gestures or buttons.
Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.
Advantages:
Excellent technical support.
Free updates.
Graphic HMIs with multi touch function can be created in minutes.
Free-of-charge development tool with test run feature.
Virtually unlimited number of pages, objects and variables.
Does not require any third-party services.
Genuine native app.
Features:
Parameters for communication such as IP address, port number, protocol, etc. can be specified per page.
Automatic polling of all variables displayed in the current page, no need for separate tag list.
Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
Prioritized event-driven transfer to the controller.
Pages are edited in the measurement unit dp (Density Independent Pixels).
Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
Detailed diagnostics of connection and communication.
Variable areas for system variables, local variables and constants.
Possibility of automatic return to the start page after some time of inactivity.
Selectable order for high and low words of 32-bit variables in the Modbus protocol.
Poll interval can be set do save data traffic or battery.
Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
Ability to test run pages in the development tool.
LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
Background color for pages can be selected.
Modbus Device ID can be changed with GUI objects during operation.
Image buttons.
Password fields.
Floating point and hexadecimal number formatting.
Timestamp for page files.
Hyperlinks.
Document information in page files.
Implemented protocols in the current version:
Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.
Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).
Modbus RTU: Class 0 and 1.
Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.
(Default value for highest Siemens S7 databock is 255.)
Free-of-charge development tool for creating the pages to be used by Odrid HMI:
https://www.idea-teknik.com/odrid_hmi_download.html
Manual:
https://www.idea-teknik.com/odrid_hmi_manual.html
Version history:
https://www.idea-teknik.com/odrid_hmi_version_history.html
Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.
S7 and STEP 7 are trademarks of Siemens AG.
- Apple App Store
- Payant
- Productivité
Classement dans le store
- -
Comparaison des classements ModTest Pro vs. Odrid HMI
Comparez l'évolution du classement de ModTest Pro au cours des 28 derniers jours à celle de Odrid HMI.
Rank
Aucune donnée disponible
Comparaison des classements ModTest Pro et Odrid HMI par pays
Comparez l'évolution du classement de ModTest Pro au cours des 28 derniers jours à celle de Odrid HMI.
Toutes les catégories
Aucune donnée disponible
Productivité
Comparez avec n'importe quel site grâce à notre essai gratuit
ModTest Pro VS.
Odrid HMI
26écembre d, 2024