Fan Spec Performance vs Heat Exchanger Area Uso & Estadísticas

FanSpec helps to evaluate different fan specification for a given application based performance characteristics such as flow rate, static pressure, shaft power, and fan efficiency. It also determines the average duct velocity duct pressure loss and duct leakage rates that are very critical to satisfactory performance and energy efficiency. Users can create multiple applications of fan-duct system and then save it in a file for evaluation and review. Most manufacturers provide fan performance data in the form of fan curve (Q vs H). However, the operating point on this curve depends upon the total resistance offered by the duct system. This app helps application engineers to quickly evaluate different options available in selection and application of fans. One can chose either SI or USCS system of units for input and outputs as shown in the screen shots. Fan properties: Fans are categorized based on the type of flow. The flow can be either axial or radial by centrifugal action based on type of application it is employed. In either case one can edit and enter key fan specification data as shown in the following screen shot. Gas properties: By default Air is used as gas medium and its properties are updated based on the input temperature. For gases other than air, the property data such as density, viscosity at given temperature for better accuracy. Duct system Users can choose any duct system based on cross section, class, size and material. Upon selection, app auto updates the duct leakage rates as per recommended standards. The total equivalent length data is used for evaluation of duct losses that includes resistance due to different duct fittings and terminal box etc. Performance summary: A comprehensive summary is provided as shown in the screen shot that includes different performance characteristics of a fan-duct system. This would help in evaluation of different fans for a given application. App notes is provided for a quick reference that has brief descriptions of different fan performance characteristics. In addition link is provided to a complete documentation on implementation and validation of different math-models used in all apps.
  • App Store de Apple
  • Pagado
  • Servicios públicos

Clasificación de tiendas

- -

This app is used to Calculate Required Surface area of tubular Heat Exchangers and No. of Tubes Required for Desired Heat Exchange is calculated in this app. This app is useful for those who are working in process industry, heat exchanger manufacturing industry and fabrication of process equipment field. this app has both mm and inches setting options. In this app Surface area of heat exchanger is calculated by taking input from user as Tube Diameter, tube length and No of Tubes of heat exchanger. In this app No of Tubes required for desired heat exchange is calculated by taking input from user as Tube Diameter, tube length in and Surface area of heat exchanger. it is very handy tool for Tubular heat exchanger maufacturing processional., mechanical engineers and proces engineers.
  • App Store de Apple
  • Pagado
  • Servicios públicos

Clasificación de tiendas

- -

Fan Spec Performance frente a Heat Exchanger Area: comparación de la clasificación

Comparar la tendencia de clasificación de Fan Spec Performance en los últimos 28 días con Heat Exchanger Area

Rank

No hay datos disponibles

Comparación de las clasificaciones Fan Spec Performance frente a Heat Exchanger Area por países

Comparar la tendencia de clasificación de Fan Spec Performance en los últimos 28 días con Heat Exchanger Area

No hay datos para mostrar

Compara con cualquier sitio gracias a nuestra prueba gratuita

Empieza ya
Fan Spec Performance VS.
Heat Exchanger Area

15iciembre d, 2024